In line chlorinator updated*

In line chlorinator updated*
1) this is NOT NSFpw certified, so although it is heavily built it can be whatever plastic Taiwan uses
2) If it does not work well for you, the company (Robert) will honor their satisfaction guarantee. At least they did for me after some long emails.

Be aware that the directions need updated and leave out the following to work 100% You must:

A) have your water hardness tested, if it s over 5 -7 gpg you MUST install your softener before the unit (not ideal)
B) you MUST install a check valve (do not trust any optional verbiage in the directions).
C) you Cannot Use smaller than 1 feed lines
D) you Cannot Have an elbow within about 4 feet of the unit on either side. I was not supplied install photos other than the manual which states nothing about bends or pipe size and instead relied on the ones for the unit Clean water store sells (which shows elbows), coincidentally That unit is named the 400 feeder, which these Vitasalus installation manuals refer to.
F) they recommend an experienced plumber install the unit, however since it s not NSF certified I had trouble finding one in my area, they would only do liquid injections.

So if you have soft water, a lot of space to run straight lines all over your basement, and don t mind chemicals this will work for you.